Schiedel IGNIS PROTECT

Designed specifically for air tight, energy efficient and timber framed buildings

In order to meet the latest European building regulations, specific leakage and performance criteria have to be met, which are much more stringent than in the past. These criteria are key in relation to chimney products passing through combustible walls.

Ignis Protect

Schiedel Chimney Systems have invested heavily to provide tested and approved solutions to resolve these challenges and are proud to introduce their latest cutting edge product designed specifically for Air Tight, Energy Efficient and Timber Framed Buildings.

Ignis Protect
Ignis Protect

Features

Product Features

  • Suitable for SW and DW connecting flue pipes passing through interior or exterior walls made of combustible materials
  • Available in two versions:
    • For exterior walls (with aluminum laminate on inside face)
    • For interior walls (without aluminum laminate and with an extended removable core)
  • Available in both 90° and 45° versions
  • For flue gas temperature up to:
    • 450 °C for SW connecting flue pipes (T450)
    • 600 °C for DW connecting flue pipes(T600)
  • Max. 100 °C surface temperature during soot fire
  • Monolithic component made of mineral wool, density 120 kg/m³, building material class A1
  • Internal face finished with aluminum laminate
  • External face made with textured surface to facilitate facade rendering
  • Removable pipe sections DN 125, 130, 150, 180, 200 mm
  • IGNIS-PROTECT can be used without any additional protection
  • Available in a range of standard wall thicknesses between 100mm -500mm
Ignis Protect

Technical Specification

DIBt
Zulassungs Nr. Z-7.4-3372 Deutsches Institut für Batechnik

  • Z-7.4-3372 relating to T450 designated products
  • Z-7.4-3402 relating to T600 designated products

Components & Systems

CP Ignis-Protect SAP Code Thickness (mm) Dims H x W (mm) Pallet Quantity
90˚ Version 101841 150 700 x 565 12
101842 200 700 x 565 9
101843 250 700 x 565 6
101844 300 700 x 565 4
101845 350 700 x 565 4
101846 400 700 x 565 2
45˚ Version 149530 100 1020 x 565 18
149531 150 1020 x 565 12
149532 200 1020 x 565 9
149533 250 1320 x 565 6
149534 300 1320 x 565 4
149535 350 1320 x 565 4
144536 400 1320 x 565 2
144032 450 1320 x 565 2
144033 466 1320 x 565 2
144034 500 1320 x 565 2

Typical Installations

Use of 90° Ignis-Protect System in accordance with BS EN 15287-1 Acceptable alternative methods of connection methods
Where a horizontal connecting flue of more than 150mm is required to connect a solid fuel fired appliance to a chimney, an installation
method as per the examples below may be used provided the following criteria is met:-

a) The maximum length of horizontal connecting flue pipe does not exceed 450mm;
b) A Defra exempt appliance or an appliance, which is limited to burning authorised smokeless fuel only, is installed;
c) A calculation according to BS EN13384-1 has indicated safe operation of the proposed configuration, and the results of the calculation are left with the householder along with the appliance installation instructions;
d) The appliance manufacturer agrees in writing to the proposed configuration;
e) The chimney manufacturer agrees in writing to the proposed configuration;
f) The total length of single wall connecting flue pipe is not more than 1.5m;
g) The appropriate distances to combustible materials from both the appliance and the connecting flue pipe are maintained.

Ignis Protect
Ignis Protect
Ignis Protect
Ignis Protect
Ignis Protect
Ignis Protect

Get in touch for more information

Personal Data
Contact and inquiry
Browse...

Maximum 10MB

Please note our data protection regulations, which are the basis for any use of data by Schiedel GmbH & Co KG.
Please wait...